Evaluating the performance of containers on a case-by-case basis is always recommended. But increased assurance about the compatibility of glass containers with cold storage conditions is key for pharmaceutical companies facing development issues with mRNA vaccines. In this increasingly complex application, Stevanato Group glass vials are a proven solution to make life easier for customers.
CCI was tested with a deterministic technique, Laser-based Headspace-Gas Analysis, measuring the concentration of CO2 gas present in the headspace of the vial. In this study, the analysis was conducted on manually and automatically assembled vials with multiple stopper configurations, at multiple timepoints after storage at room temperature and at -80°C. Seven (7) combinations were tested, each with 30 samples at T0,T6 and T24 months, and all configurations passed, showing that CCI was maintained.
Given that final container closure configuration is process and material dependent, a dedicated study is mandatory to ensure the suitability of the selected configuration for the required application.
Test Approach
The objective of these tests was to identify and determine the impact (if any) on glass vials’ mechanical resistance to Axial Load and Internal Pressure of storage conditions of -80°C over a period of 7 days. The samples for which VC and BT were evaluated were uncapped 2R vials to evaluate only the impact on the glass container itself.
VC and BT were performed on empty vials with and without Deep Freezing conditioning to verify any differences in behaviour caused by the conditioning itself.
VC and BT tests were performed using a Zwick Roell Z050 universal testing machine.
Figure 1: a) Example of sample before Vertical Compression. b) Example of sample after Vertical Compression.
Figure 2: a) Example of sample before Burst Test. b) Example of sample after Burst Test.
The categories tested were 2R vials according to ISO 8362-1, with two different configurations:
The objective of this test was to determine CCI during stability at 25°C/60% RH and -80°C at three different time points (T0, T6 and T24 months) over a storage period of 24 months.
The samples for which CCI was evaluated were 2R vials with different cap methods: stoppered with aluminum crimped cap and capped with a press-fit cap.
CCI testing was conducted using Headspace Gas Analysis, based on the measurement of the headspace carbon dioxide content in the samples after exposure to a carbon dioxide enriched environment at the target temperatures.
The categories tested were 2R vials according to ISO 8362-1, with only one configuration:
Test results and conclusions
The results of the two categories tested with VT and BT are summarized below:
The following effects can be asserted:
In Table, the HGA CCI test results are summarized for each tested configuration under every condition.
The following effects can be asserted: